Low noise level, it is the ideal generator for use in residential areas or outside normal working hours. It’s equipped with a reliable Diesel engine, first class components and complete instrumentation.
Pramac P4500 230V 50HZ #CONN #DPP, 1 Year Warranty
Pramac
$6,014.80 (incl. GST)
The Shipping will be initiated within approximately two business days following the receipt of payment.
Specifications
Engine specifications | Units | |
---|---|---|
Engine manufacturer | Yanmar | |
Model | L70N | |
Engine cooling system | Air | |
Displacement | cm³ | 320 |
Aspiration | Natural | |
Operating Speed-Nominal | rpm | 3000 |
Speed governor | Mechanical | |
Fuel | Diesel | |
Oil capacity | (â„“) Litre | 1.1 |
Starting system | Electric |
Dimensions
Length | (L) mm | 800 |
Width | (W) mm | 520 |
Height | (H) mm | 837 |
Dry weight | Kg | 99 |
Fuel tank capacity | l | 18 |
Alternator
Alternator specifications | Units | |
---|---|---|
Type | ||
Class | H | |
IP protection | 23 | |
Poles | 2 | |
Frequency | Hz | 50 |
Voltage regulation system | Capacitor |
Autonomy
Fuel consumption at 75% of Load | l/h | 1.15 |
Fuel consumption at 100% of Load | l/h | 1.24 |
Running time at 75% of load | h | 15.65 |
Running time at 100% of load | h | 14.52 |
Noise Level
Guaranteed noise level (LWA) | dB(A | 96 |
Noise pressure level @ 7 m | dB(A | 68 |
Genset Control Panels (CONN DPP)
Mounted on the genset and complete of: instrumentation, control, protection of the generating set and sockets.
COMMANDS:
- Start selector switch with key: OFF – ON – START
- CONNector for AMF/RSS (Accessory available)
INSTRUMENTATION:
- Voltmeter
PROTECTIONS
- Circuit breaker
- Cover protection circuit breaker IP55
- Differential protection (DPP)
- Low Oil Pressure
SOCKET TYPE
SCHUKO 230V 16A IP54 | 1 |
2P+T CEE 230V 16A IP44 | 1 |
2P+T CEE 230V 32A IP44 | 1 |
Accessories Control Panel*
AMF – AUTOMATIC CONTROL PANEL (CONN)
This accessory permits to control all the functions about a generator. It’s built to monitor mono phase or three phase with neutral systems in alternate current; it permits to transfer the user’s load on generator when the mains voltage is faulty.
Conversely, as soon as AMF system detects the power grid, it stops the generator.
Equipment:
- Control and protection unit (DGT)
- Phase detector
- Contactor with interblock
- Battery charged
- Acustic alarm
- 8 meters control wiring (with CONNector)
- External start stop capability
- Emergency stop button
Instrumentation (DGT):
- Mains voltage
- Genset voltage
- Frequency meter
- Hour meter
Alarm & Shutdowns:
- Generators voltage out of limits
- Battery Voltage out of limits
- Low oil Pressure
- Fail to start
- External shutdown
RSS – REMOTE START / STOP (CONN)
RSS Remote start/stop wireless with CONNector (max Distance 90m)
*Accessories Sold Separately
Accessories*
TRANSPORTATION KIT
With Fix Handle
With Folding Handles
LIGHT TOWER
for portable generators (with tubular frames)
- Maximum Height 4.2m
- Elevations Pneumatic
- Quick open/close systems for legs
- Mast support and four lifting
- Lamp available Watt/Type:
- n.4 X 500W Halogen (required power from generator: 2.5kVA 230V Single Phase)
- n.4 X 1000W Halogen (required power from generator: 5,0kVA 230V Single Phase)
MTS- MANUAL TRANSFER SWITCH
*Accessories Sold Separately
Description
GENERATING SET P4500 Silenced +CONN +RCD, Single phase, 230V, 50Hz, Yanmar Engine, Electric start / Diesel + HAU4
Ratings definition (According to standard ISO8528 1:2005)
COP – Continuous Power:
It is defined as being the maximum power which a generating set is capable of delivering continuously for an unlimited number of hours, with the maintenance intervals and procedures being carried out as prescribed by the manufacturers.
LTP – Limited-Time running Power:
It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available
Main Features | Units | |
---|---|---|
Frequency | Hz | 50 |
Voltage | V | 230 |
Power Factor | cos Ï• | 0.9 |
Phase | 1 |
Power Rating | Units | |
---|---|---|
Standby Power LTP | kVA | 4.1 |
Standby Power LTP | kW | 3.7 |
Continuous power COP | kVA | 3.5 |
Continuous power COP | kW | 3.1 |
Glossary
CONN
Connector
DPP
Differential Power Protection
Reviews
There are no reviews yet.