Low noise level, it is the ideal generator for use in residential areas or outside normal working hours. It’s equipped with a reliable Diesel engine, first class components and complete instrumentation.
Pramac P11000 + AMF 230V 50HZ #IPP, 1-Year Warranty
Pramac
$13,739.00 (incl. GST)
The Shipping will be initiated within approximately two business days following the receipt of payment.
Specifications
Engine specifications | Units | |
---|---|---|
Engine manufacturer | Yanmar | |
Model | 3TNV70-HGE | |
Engine cooling system | Water | |
Displacement | cm³ | 854 |
Aspiration | Natural | |
Operating Speed-Nominal | rpm | 3000 |
Speed governor | Mechanical | |
Fuel | Diesel | |
Oil capacity | (â„“) Litre | 3.8 |
Coolant capacity | (â„“) Litre | 0.9 |
Starting system | Electric | |
Electric circuit | V | 12 |
Dimensions
Length | (L) mm | 1400 |
Width | (W) mm | 650 |
Height | (H) mm | 975 |
Dry weight | Kg | 325 |
Fuel tank capacity | l | 24 |
Alternator
Alternator specifications | Units | |
---|---|---|
Class | H | |
IP protection | 23 | |
Poles | 2 | |
Frequency | Hz | 50 |
Voltage regulation system | Capacitor |
Autonomy
Fuel consumption @ 75% PRP | l/h | 3.05 |
Fuel consumption @ 100% PRP | l/h | 3.97 |
Running time @ 75% PRP | h | 7.87 |
Running time @ 100% PRP | h | 6.05 |
Noise Level
Guaranteed noise level (LWA) | dB(A) | 96 |
Noise pressure level @ 7 m | dB(A) | 68 |
Genset Manual Control Panels MCP #IPP
Mounted on the genset and complete of: instrumentation, control, protection of the generating set and sockets.
COMMANDS
- Start selector switch with key: OFF – ON – START
INSTRUMENTATION
- Voltmeter
- Hourmeter
- Low oil pressure Alarm Lamp
PROTECTIONS
- Circuit breaker
- Isometer protection (IPP)
- Oil pressure indicator
SOCKET TYPE
2P+T CEE 230V 16A IP44 | 2 |
2P+T CEE 230V 32A IP44 | 1 |
SUPPLEMENTS CONTROL (Available when ordered)
AMF – AUTOMATIC MAIN FAILURE
This version permits to control all the functions about a generator. It’s built to monitor mono phase or three phase with neutral systems in alternate current; it permits to transfer the user’s load on generator when the mains voltage is faulty. Conversely, as soon as AMF system detects the power grid, it stops the generator.
Equipment:
- Control and protection unit (DGT)
- Phase detector
- Contactor with interblock
- Battery charged
- Acustic alarm
- Esternal start stop capability
- Emergency stop button
Instrumentation (DGT)
- Mains voltage
- Genset voltage
- Frequency meter
- Hour meter
Alarm & Shutdowns:
- Generators voltage out of limits
- Battery Voltage out of limits
- Low oil Pressure
- Fail to start
- External shutdown
Note: The AMF panel (Automatic Control Panel) replaces the Manual Control Panel
PHS – Coolant pre-heating system
Coolant preheater Engine (only available for AMF version)
Accessories*
Transportation Kit
*Accessories Sold Separately
Description
GENERATING SET P11000 +AMF, Single phase, 230V, 50Hz, Yanmar Engine, Electric start / Diesel
Ratings definition (According to standard ISO8528 1:2005)
COP – Continuous Power:
It is defined as being the maximum power which a generating set is capable of delivering continuously for an unlimited number of hours, with the maintenance intervals and procedures being carried out as prescribed by the manufacturers.
LTP – Limited-Time running Power:
It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available.
Main Features | Units | |
---|---|---|
Frequency | Hz | 50 |
Voltage | V | 230 |
Power Factor | cos Ï• | 0.9 |
Phase | 1 |
Power Rating | Units | |
---|---|---|
Standby Power LTP | kVA | 10.8 |
Standby Power LTP | kW | 9.7 |
Continuous power COP | kVA | 10.0 |
Continuous power COP | kW | 9.0 |
Glossary
AMF
Automatic Main Failure
IPP
Independent Power Producer
Reviews
There are no reviews yet.