A petrol generator designed specifically for intensive operations where performance power is demanded by professional user, over an extended period of time.
Pramac ES5000 230V 50HZ #AVR #DPP #HAU, 1-Year Warranty
Pramac
$2,445.30 (incl. GST)
The Shipping will be initiated within approximately two business days following the receipt of payment.
Specifications
Engine specifications | Units | |
---|---|---|
Engine Brand | Honda | |
Model | GX270 Recoil | |
Engine cooling system | Air | |
Displacement | Cm3 | 270 |
Aspiration | Natural | |
Operating Speed-Nominal | rpm | 3000 |
Speed governor Mechanical | Mechanical | |
Fuel Petrol | Petrol | |
Oil Capacity | (â„“) Litre | 1.1 |
Starting system | Recoil |
Dimensions
Length | (L) mm | 729 |
Width | (W) mm | 500 |
Height | (H) mm | 536 |
Dry weight | Kg | 61 |
Fuel tank capacity | (â„“) Litre | 11 |
Autonomy
Fuel consumption at 75% of Load | l/h | 1.66 |
Fuel consumption at 100% of Load | l/h | 2.22 |
Running time at 75% of Load | h | 6.63 |
Running time at 100% of Load | h | 4.95 |
Alternator
Alternator specifications | Units | |
---|---|---|
Type | Brushes | |
Class | H | |
IP protection | 23 | |
Poles | 2 | |
Frequency | Hz | 50 |
Voltage tolerance | % | 2 |
Voltage regulation system | Electronic | |
Standard AVR | AVR 520 |
Noise Level
Guaranteed noise level (LWA) | dB(A) | 97 |
Noise pressure level @ 7 m | dB(A) | 69 |
Genset Control
COMMANDS:
- Selector switch: OFF – ON
- Starting systems: Recoil
- Fuel Cock
PROTECTIONS STANDARD:
- Thermal Protection
- Oil Guard
DIFFERENTIAL PROTECTION (DPP):
- Differential protection 30mA
- Circuit breaker
- Hourmeter
MEN LINK
SOCKET TYPE
AS/NZS 3112 15A 250V | 2 |
Accessories*
Transportation Kit
*Accessories Sold Separately
Description
GENERATING SET ES5000 + AVR, Single phase, 230V, 50Hz, Honda Engine, Hand start / Petrol + HAU2
Ratings definition (ISO-8528)
ESP – Emergency Standby Power:
It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.
COP – Continuos Power:
It is defined as being the maximum power which a generating set is capable of delivering continuously for an unlimited number of hours, with the maintenance intervals and procedure being carried out as prescribed by the manufacturers.
Main Features | Units | |
---|---|---|
Frequency | Hz | 50 |
Voltage | V | 230 |
Power factor | cos Ï• | Â 0.9 |
Phase | 1 |
Power Rating | Units | |
---|---|---|
Emergency Standby Power | kVA | 5.1 |
Emergency Standby Power | kW | 4.6 |
Continuous power COP | kVA | 4.2 |
Continuous power COP | kW | 3.9 |
Glossary
AVR
Automatic Voltage Regulator
DPP
Differential Power Protection
HAU
High Altitude Usage
Reviews
There are no reviews yet.